7 TECHNICAL SPECIFICATION (Twin Models)
Model
QT50
Twin
QT80
Twin
QT120
Twin
Electrical
Power supply
Volts/phase freqency
230/1/50 230/1/50 230/1/50
Enclosure IPX4 IPX4 IPX4
Type of motor Induction Induction Induction
Power consumption 340 Watts 540 Watts 820 Watts
Full load current 1.5 Amps 2.4 Amps 3.6 Amps
Rating
Intermittent, 30 mins on,
30 mins off
Intermittent, 30 mins on,
30 mins off
Intermittent, 30 mins on,
30 mins off
Max. No Starts per hour 60 60 60
Mechanical
Max inlet head 8 metres 8 metres 8 metres
Max head (closed valve) 11 metres 22 metres 31 metres
Max working pressure* 270 kPa (2.7 bar) 370 kPa (3.7 bar) 480 kPa (4.8 bar)
Max ambient air temperature 40
o
C 40
o
C 40
o
C
Max water temperature** 65
o
C 65
o
C 65
o
C
Min water temperature 4
o
C4
o
C4
o
C
Pump
Dimensions
Length 277 mm 334 mm 425 mm
Width 135 mm 135 mm 135 mm
Height (excluding flexible hoses) 220 mm 220 mm 220 mm
Gross Weight 5.8 Kg 7.0 Kg 9.7 Kg